Horizontal polarized electrolytic capacitors

SA Series 105 ℃
Feature
◆ apply a high temperature, and higher reliability consumer products.
◆ High temperatures and higher reliability general industrial products.
SA Series 105 ℃
Fearures
◆ Used in Standard size for popular circuit, etc.
◆ Available in taping configuration for automatic insertion.
Technical Requirements Specifications
Project ltem characteristics Performance Characteristics
Operating temperature range
Operating Temperature Range-40to +105 ℃-25to +105 ℃
Rated voltage range
Rated Voltage Range 6.3to100VDC 160to450VDC
Capacitance Range
Capacitance Range 0.1to4700μF 0.47to220μF
Capacitance tolerance
Capacitance Tolerance +20% (100Hz or 120Hz, +20 ℃)
Leakage Current Leakage Current
(+20 ℃, the maximum max) I ≤ 0.03CV or 4 (μA) rated working voltage charging three minutes after the reading, whichever is greater I ≤ 0.01CV or 3 (μA) After3minutes, whichever is greater measured with rated working voltage applied I ≤ 0.03CV +10 (μA) rated working voltage charging three minutes after the reading,
Whichever is greater I ≤ 0.03CV +10 (μA) After
3minutes, whichever is greater measured with rated working voltage applied
Loss tangent
Dissipation Factor
(Tgδ) Operating voltage WorkingVoltabe (VDC) 6.3 10 16 25 35 50 63 100 160 200 250 350 400 450
DF (%) Max 28 24 20 16 14 12 1,010,202,020,252,525
Capacity> 1000μF, every increase of 1000μF DF value increased 2% (100Hz or 120Hz, +20 ℃)
For capacitance1000μF, Add 2% per another 1000μF (100Hz or 120Hz, +20 ℃)
Low temperature properties
Low Temperature
Characteristics
(120Hz) impedance ratio, maximum max Impedance ratio at 120HZ to the 20 ℃ value
Voltage Working Voltage (VDC) 6.3 10 16 25 35 50 63 100 160 200 250 350 400 450
DF (%) Max 28 24 20 16 14 12 1,010,202,020,252,525

High-temperature load life Load Life After 1,000 hours application of rated voltage at 105 ℃, capacitors meet the characteristics
Meet the characteristics requirements mentioned below
Ambient temperature: +105 ℃ Ambient timperature: +105 ℃
Applied voltage: Rated voltage (VDC) Applied voltage: Rated Working Voltage (DVC)
After the test requirements: Recovery 16 hours at room temperature, +20 ℃ test After test requirements: Resumde 16 hours at
normal temperature
Capacitance change: ≤ 25% specified value Capacitance change: ≤ 25% of the initial measured value
Loss tangent: ≤ 200% initial value Dissipation Factor: ≤ 200% of the initial specified value
Leakage current: ≤ specified value Leakage Current: ≤ The initial specified value
No high temperature load life test conditions Test conditions Shelt Life
Duration: 500 hours Duration time: 500hours
Ambient temperature: +105 ℃ Ambient temperature: +105 ℃
Applied voltage: None Applied voltage: None